Description
This page allows you to create a Pro Forma communication. Standard Cúram communications have been extended to allow for a multidisciplinary team member to be selected as a correspondent. Communications can be paper, telephone, or email based and can be integrated with MS Word templates, XSL templates, or email servers.
Page Preview
Page Flow Diagram
Click the diagram to manipulate and zoom. Traverse the diagram using Click-and-Drag motions. Fullscreen
Fields
LabelTypeDescriptionMandatory
Print NowCURAM_INDICATORYou can select the Print Now selection box to print the communication. The communication is printed out on your default printer. Printed hardcopy communications have a "draft" communication status. This is to allow for print version modifications. In order to change a hardcopy communication status to "sent", you must open the Modify Pro Forma Communication page and select the "sent" communication status.No
Correspondent TypeCORRESPONDENT_CODECorrespondent type that relates to a coded description of the communication correspondent, e.g., client, employer or representative.No
Correspondent
LabelTypeDescriptionMandatory
AddressSEF_ADDRESS_IDCorrespondent's address. Your organization determines the correct address formatting.Yes
Comments
LabelTypeDescriptionMandatory
Comments COMMENTSNo
Links and Actions
Page Level Actions
LabelDescription
CancelThe Cancel action dismisses the page.
SaveThe Save action creates a new record from the information entered on the page.
Messages
When page is loaded
MessageMessage CatalogConfigurableConfigurable Validation Reference ID
Address data line %1n is not in correct format.LinkNo
Address header information is missing or invalid.LinkNo
An Exception occurred as the timeout has been reached and the transaction has been rolled back.LinkNo
Attempt to map a freeform address as a non-freeform.LinkNo
Invalid address layout type %1s specified in address header.LinkNo
No name tag specified in address data line %1n.LinkNo
No security implementation is supported for this transaction type. Please contact an Administrator.LinkNo
The end date of the primary address has passed.LinkNo
The end date of the primary email address has passedLinkNo
The end date of the primary phone number must not be in the past.LinkYesbpomaintainconcernrolephone.err_concernroleephone_fv_date_passed|a|
The login ID %1s does not map to a user name.LinkNo
When page is submitted
MessageMessage CatalogConfigurableConfigurable Validation Reference ID
%1s %2s %3s %4sLinkNo
%1s has no address and cannot receive communications. You must supply an address.LinkNo
A communication date must be provided if the status is changed to Sent.LinkNo
Address header information is missing or invalid.LinkNo
An entity identifier cannot be null.LinkNo
An Exception occurred as the timeout has been reached and the transaction has been rolled back.LinkNo
An exception occurred in the print stream - Failed to get the expected response from the XML server: %1sLinkNo
Case status with corresponding case ID %1s was not found.LinkNo
Failed to get a response from the XML server.LinkNo
If the correspondent is not the client the correspondent type must not be of type Client.LinkNo
If the correspondent is not the primary client the correspondent type must not be of type Client.LinkNo
If the correspondent is the client then the correspondent type must be Client.LinkNo
If the correspondent is the primary client then the correspondent type must be Client.LinkNo
Invalid address layout type %1s specified in address header.LinkNo
Last Name is not available for the Prospect Person. Please enter the Last Name from the Prospect Person home page.LinkNo
More than entity of type '%1s' with key value '%2s' found in the cache.LinkNo
New communication details cannot be added for a client that is currently marked as a duplicate.LinkNo
No case event records found for case ID %1s.LinkNo
No concrete DAO specified for discriminator value '%1s'.LinkNo
No database access is allowed at this point.LinkNo
No security implementation is supported for this transaction type. Please contact an Administrator.LinkNo
Pro forma template ID %1s was not found.LinkNo
System configuration error - Unable to retrieve system user details from the database. Please contact your system administrator.LinkNo
The class '%1s' does not implement the interface curam.util.events.impl.EventFilter and therefore is not as an event filter.LinkNo
The class '%1s' does not implement the interface curam.util.events.impl.EventHandler therefore is not an event handler.LinkNo
The document cannot be printed as it is in an unexpected format. Please contact your system administrator.LinkNo
The event filter: '%1s' could not be instantiated.LinkNo
The event handler: '%1s' could not be instantiated.LinkNo
The Key Server cache and the Key Server database values are out of sync and therefore this record cannot be inserted. LinkNo
The list of XML server host names and ports must be equal.LinkNo
The login ID %1s does not map to a user name.LinkNo
There are no closure details on this caseLinkNo
There was a problem closing the socket to the XMLServer.LinkNo
The Social Enterprise Folder is closed it cannot be modified.LinkNo
The specified template could not be found.LinkNo
This communication cannot be previewed/printed as this case has never been closed.LinkNo
This communication cannot be previewed/printed as this case has not been unsuspended.LinkNo
This communication cannot be previewed/printed as this case is not closed.LinkNo
This communication cannot be previewed/printed as this case is not suspended.LinkNo
You cannot modify this record as it has been deleted.LinkNo
You do not have access to this case note.LinkNo
You have selected %1c as the communication method. %2s has a communication exception for this method.LinkNo
You must supply a correspondent name for this communication.LinkNo
Workflows
When page is loaded
None
When page is submitted
WorkflowDescription
COMMUNICATIONSFORDUPLICATECLIENTNotifies the case owner of a case that a communication has been created within the case for a case participant that is a duplicate client.
Related Entities
Technical Information
Page IDSocialEnterpriseFolder_createProFormaCommunication
LocationC:\Users\david\dev\src\esystems-inc\Curam_V8_IS\webclient\components\SocialEnterpriseCollaboration\SEF\Application\Communication\SocialEnterpriseFolder_createProFormaCommunication.uim
Page Load InterfaceSocialEnterpriseFolderCommunication.getCorrespondentDefaults
Page Submit InterfaceSocialEnterpriseFolderCommunication.createProForma
Linked From PagesNew Pro Forma Communication (SocialEnterpriseFolder_selectProFormaType)